TECHNICAL REPORT -
dimensional based particulars
Title of Technical Report:
"Municipal castings. Manhole tops. Covers, – lids and frames, – for use in vehicular and pedestrian areas."
"Particulars of product; Dimensional specification, – RD 630 mm \ 25.0 in."
"Assembly of lids and frames – medium duty loading class – 80/125/150 kN / 25,000/(16,000…40,000) LBS."
Title of Technical Report:
"Municipal castings. Manhole tops. Covers, – lids and frames, – for use in vehicular and pedestrian areas."
"Particulars of product; Dimensional specification, – RD 630 mm \ 25.0 in."
"Assembly of lids and frames – medium duty loading class – 80/125/150 kN / 25,000/(16,000…40,000) LBS."
Relevant documents to
be considered: Basic standards, as are AASHTO(M306), GOST3634,
EN124, and similar.
The dimensional particulars refers to medium duty manhole covers of 80/125/150 kN or 25,000/(16,000…40,000) LBS loading class – which are commonly casted by medium or high grade grey iron or medium grade ductile iron in compliance with loading class and pieces structure (plates/walls/reinforcements).
Note!
Hinges or locking devices are not subject of the Technical Report.
The dimensional particulars refers to medium duty manhole covers of 80/125/150 kN or 25,000/(16,000…40,000) LBS loading class – which are commonly casted by medium or high grade grey iron or medium grade ductile iron in compliance with loading class and pieces structure (plates/walls/reinforcements).
Note!
Hinges or locking devices are not subject of the Technical Report.
Measurements in metric
or in English units must be considered apart.
Mechanical drawings in which the
Technical Report consists – are considered as drafts, and there are
provided as-is.
Dimensions which are not mentioned, no matter there are or not structural thickness of pieces, are not the subject of the Technical Report, mainly because each manufacturer is setting them as he considers properly.
Lids description:Dimensions which are not mentioned, no matter there are or not structural thickness of pieces, are not the subject of the Technical Report, mainly because each manufacturer is setting them as he considers properly.
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhIJnIRlZTD0gZlcYg_jnm2IXN0lTgnKPmDBnZb6NTMKaVTthKkB43U8hVU8R_UB0lCq7ZyXWCj1iZ3y0thlc9H0TZfiNM-hsRYFu90t37SlpHdgsO5h8Swbiv6FarjcxKkAZ1W9d3cQjc/s400/630-i1m8e-gro-CC-front1.gif)
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjFJNgZucd3GnoXUgD9QxkcofytEG9D_WPEXjDYr1_j8bXV9oXYz-K_gm6WZrt_ZqDnLr2UVA_Qz9gxDEjp-MJMtnrdXihn2oMAsNKjaNH2WlVwadj3V0JtoFleQxQJjgxBApBCYEBw_pQ/s400/630-mc2-24%2523-CC-front.gif)
Frames description: